
Precision Gastric Motility –
Anywhere,
Safe & Simple
GastricTime replaces complex hospital-bound motility tests with a radiation-free, battery-free swallowable capsule
and wearable reader – delivering actionable motility data at the point of care.
A Critical Clinical Variable
Missing From Routine Care
Gastric motility disorders affect millions worldwide – yet objective measurement remains absent from routine care. The rapid adoption of GLP-1 receptor agonists has made this diagnostic gap more consequential than ever.
Clinicians Are Making High-Stakes Decisions Without Data
When GI symptoms arise, clinicians cannot objectively distinguish drug-induced motility changes from underlying pathology. Without that data, patients face an impossible tradeoff – abandoning treatments that may still be right for them, or continuing without knowing whether genuine gastroparesis is present.
Gastric Motility Is a Critical Variable Across Metabolic Care
From determining insulin timing in personalized diabetes management, to evaluating candidates for bariatric surgery and monitoring outcomes post-procedure – objective gastric emptying data is needed across multiple high-stakes clinical decisions. Today, it is routinely absent.
Current Gold Standard: Scintigraphy
- Hospital-bound – requires nuclear medicine facilities
- Radioactive meal required for imaging
- $1,200 per test – facility-based cost
- 4–6 hour sessions – impractical for repeat testing
- Requires specialized imaging staff
Consequence: Untreated Diagnostic Gap
- Premature GLP-1 discontinuation despite potential benefit
- Inappropriate dose escalation or reduction
- Unnecessary referrals, imaging, or drug switching
- Lost therapeutic value in high-cost treatments
- Risk of aspiration in undiagnosed gastroparesis patients
Simple Measurement,
Actionable Insight
A swallowable capsule dissolves in the stomach, releasing passive RFID tags that are individually detected as they transit the pylorus – no batteries, no radiation, no hospital required.
Wearable Reader Placement

Capsule & Meal Ingestion

Intragastric Tag Dispersion

Precision Pyloric Detection

AI-Powered Clinical Output


US Provisional Patent Application No. 63/837,170
Cost, Simplicity, and
Repeatability at Scale
GastricTime is designed not to replace the specialist – but to bring objective motility measurement into every care setting.
| Attribute | Scintigraphy | Wireless Motility Capsule | GastricTime |
|---|---|---|---|
| Radiation & Toxicity | × Radioactive | × Ingested Battery | ✓ Passive RFID – no radiation, no battery |
| Cost | × Expensive | × Expensive | ✓ Affordable |
| Test Setting | × Hospital / Nuclear medicine | △ Specialty GI center | ✓ Primary care / Outpatient |
| Test Duration | △ 4–6 hours imaging | × 8–48 hours total | ✓ 2–4 hours gastric-specific |
Built by Those Who Have
Done It Before
GastricTime was founded by veterans of the MedTech industry – with decades of combined experience developing and commercializing GI innovations globally.
Scientific Advisory Board

Building the Standard Measurement Layer for
Metabolic & GI Care
We are seeking strategic investors and clinical partners to advance the next phase of development.



